Topol IP public address — a digital security voice alarm system (SVAS) fully built into your security system. The operator's voice, pre-recorded messages or automatic warnings sound across the perimeter and indoors with Hi-Fi quality and zero delay — over the same Topol API network as intrusion detection, CCTV and automation.
Topol IP public address — digital security voice alarm system
Hi-Fi quality · zero delay · single Topol API networkoperator's voice, pre-recorded message or music broadcast
central units process the audio and route it to the zone over the Topol API
boost the signal in the zone
transformer isolation, noise-immune
outdoor horns and indoor speakers
• Line length: very long zone reach on standard cable with minimal losses
• Scaling: unlimited number of zones and total power
• Loudspeakers: each horn's power is independent thanks to transformer taps
• Noise immunity: noise-immune high-voltage line
• Safety: transformer isolation — galvanic separation
Low current at a high line voltage — crisp and loud sound even at the farthest horn; new loudspeakers can be added without redesign
No separate server or own communication lines: everything runs through the central processing unit (BOS) over the same data backbone as the whole Topol system.
noise immunity, galvanic separation
unlimited zones and total power
How it works
The alarm system runs over a single digital backbone. The operator broadcasts a message from a workstation (HMI) or a microphone console (MCU) — pre-recorded, live, or a music broadcast. The central BOS-C and BOS-C-VO units process the audio and route it over the Topol API network to the target zone. There buffer amplifiers boost the signal, and a 110 V high-voltage line with transformer isolation delivers it to the loudspeakers — outdoor horns and indoor speakers.
The system serves both as an informational tool (messages to staff) and a deterrent (voice address to an intruder on the perimeter). The number of zones and their total power are unlimited.
Why it matters on a protected perimeter
The human voice is the fastest and clearest deterrence tool. On a protected perimeter, voice alerting:
- warns an intruder by voice before the guard arrives — "You are in a secured area, leave immediately";
- works in any weather and at night, when visual means are limited;
- reacts automatically to security-line alarms: when an intrusion event occurs in a zone, a prepared message plays there;
- amplifies other security means — together with alarm lighting and CCTV it creates a convincing "live" perimeter;
- supports informational broadcasts for staff across sites of any size.
Why 110 V transformer-based audio beats low-voltage systems
Most "ordinary" alarm systems use low-voltage lines (4–8 Ω). On a long perimeter this is the weak point: high currents cause heavy losses, thick expensive cable is required, and every new loudspeaker has to be squeezed into the amplifier's load budget.
Our system uses a 110 V high-voltage line with transformer isolation — and that changes the rules:
| Parameter | Low-voltage system (4–8 Ω) | Our system — 110 V, transformer audio |
|---|---|---|
| Line length | Limited by losses; thick cable required | Very long zone reach on standard cable with minimal losses |
| Scaling | Each zone needs its own amplifier and a load recalculation | Unlimited number of zones and total power |
| Loudspeaker connection | Load changes affect the amplifier | Each horn's power is independent thanks to transformer taps |
| Noise immunity | Vulnerable to induced noise on long lines | Noise-immune high-voltage line |
| Safety | High currents in the line | Transformer isolation — galvanic separation |
Low current at a high line voltage means low losses: the sound reaches the farthest horn crisp and loud, and new loudspeakers can be added to the same line without redesign.
No separate server or communication lines
The alarm system needs neither a separate server nor its own communication lines. Everything runs through the security system's central processing unit (BOS) and over the same data backbone as the whole Topol system. That means: one infrastructure, one control centre, minimal cabling and hardware — and the public address is already integrated with perimeter security.

System capabilities
- Single information network based on the Topol control API;
- data link with no delay and Hi-Fi quality between all elements;
- noise-immune 110 V line from amplifiers to loudspeakers;
- broadcast of operator messages from control consoles, pre-recorded messages and music broadcasts;
- wide choice of outdoor and indoor loudspeakers, including horn type with IP65 enclosure protection;
- control of light and information signs;
- full integration into the central signal processing units;
- perimeter cabinets with a built-in amplifier.