Gas Detection Systems

In two words. DG-series gas detectors monitor concentrations of hazardous gases (methane, propane, carbon monoxide) in indoor and outdoor environments. Output — RS-485 + relays, built-in audible alarm, operating down to −40 °C. Used at gas stations, parking garages, boiler rooms, oil storage, and industrial facilities.

DG gas detectors — 7 models in one section

Methane, propane, carbon monoxide (CO) · alarm thresholds, differences and application recommendations
METHANE & PROPANE (CH₄/C₃H₈) — alarm thresholds in % LEL: 20 % (DG-1) and two-stage 10/40 % (DG-2, DG-4). Models: DG-1-PM, DG-2-PM, DG-4-PM.
CARBON MONOXIDE (CO) — threshold 50 / 100 ppm, exhaust gas detection. Models: DG-1-U, DG-2-U, DG-4-U.
Common specifications (all models)
• Supply voltage: 11–28 V
• Operating temperature: −40…+50 °C
• Indication: "Standby", "Alarm", "Fault"
• Built-in audible alarm
• Service life: at least 5 years
• MTBF: at least 15,000 h
• Dimensions: 140×96×55 mm, weight ≤ 270 g
• Mounting: wall-mounted
How to choose a model
Methane + propane
single threshold 20 % LEL
→ DG-1-PM
Two-stage CH₄
threshold 10/40 %
→ DG-2-PM / DG-4-PM
CO — parking
50 / 100 ppm
→ DG-1-U / DG-4-U
CO, 2 channels
50 / 100 ppm
→ DG-2-U
CO + hydrocarbons
combined threshold
→ DG-1-UPM
All models
IP65, 11–28 V, −40…+50 °C
wall-mounted

DG Gas Detectors

Model Gas(es) Alarm threshold Output Protection
DG-1-PM Methane + Propane CH₄: 20 % LEL, C₃H₈: 20 % LEL RS-485 + 2 relays IP65
DG-1-U Carbon monoxide (CO) 50 / 100 ppm RS-485 + 2 relays IP65
DG-1-UPM CO + Methane + Propane Combined RS-485 + 2 relays IP65
DG-2-PM Methane + Propane (2 ch) CH₄: 10/40 %, C₃H₈: 20 % RS-485 + 2 relays IP65
DG-2-U CO (2 ch) 50 / 100 ppm RS-485 + 2 relays IP65
DG-4-PM Methane + Propane CH₄: 10/40 %, C₃H₈: 20 % RS-485 + 2 relays IP65
DG-4-U CO 50 / 100 ppm RS-485 + 2 relays IP65

Common specifications:

  • Supply voltage: 11–28 V
  • Operating temperature: −40…+50 °C
  • Indication: "Standby", "Alarm", "Fault"
  • Built-in audible alarm
  • Service life: ≥ 5 years
  • MTBF: ≥ 15,000 h
  • Dimensions: 140×96×55 mm, weight ≤ 270 g
  • Mounting: wall-mounted

Applications

  • Gas stations & oil depots — methane and propane leak detection
  • Underground parking — CO detection from exhaust fumes
  • Boiler rooms & gas distribution — natural gas monitoring
  • Industrial plants — toxic gas monitoring
  • Flammable storage — explosion hazard prevention

Documentation

Model Passport
DG-4-PM PS