Addressable sensors
In a nutshell. Individual sensors are fastened to the fence or buried in the ground, each responsible for its own small section (from 3 to 50 m) and "knowing" its place in the line. The processing unit sees exactly which sensor was triggered — so the system pinpoints the location of a breach even in a difficult interference environment. VD-3, VD-5 and VD-5-K are vibration sensors on the fence (MEMS accelerometer), SD-3 is a seismic sensor in the ground, DD-1 is an addressable amplifier for triboelectric cable.
Addressable sensors connect to the control units over RS-485 lines — directly or via a fiber-optic communication line using BOS-L linear processing units. This is how a long, sensor-rich security system is built with a minimum of cable routes.
| Device | Purpose | Protected zone of one sensor | Detection accuracy | Transport security certificate | Extended frequency range | Spectral subtraction |
|---|---|---|---|---|---|---|
| Vibration addressable VD-5 | Mesh, profiled-sheet and wooden fences | 3–9 m | 3–9 m | Yes | No | Yes |
| Vibration addressable VD-5-K | Mesh, profiled-sheet and wooden fences | 3–9 m | 3–9 m | Yes | Yes | Yes |
| Vibration addressable VD-3 | Mesh, profiled-sheet and wooden fences | 3–9 m | 3–9 m | No | No | No |
| Vibration addressable extended DD-1 | Razor tape, soft coping arms | 2 arms of up to 30 m (per data sheet) | 30 m | Yes | No | No |
| Seismic addressable extended DD-1 | Ground under the fence | 2 arms of up to 30 m (per data sheet) | 30 m | Yes | No | No |
| Seismic addressable SD-3 | Hidden security line in the ground | 5 m | 5 m | Yes | No | Yes |
Thanks to the high detection accuracy and the small protected zone, addressable sensors work together with a spatial-temporal data-processing algorithm. The system:
- determines localised actions on the fence by comparing energy levels between sensors in comparison zones;
- matches the action against the intruder profile: compared with the reference test climb-over and data from neighbouring sensors, it determines the target type (person, vehicle, animal, bird) and whether the effort applied is sufficient to get over the fence;
- assesses the noise level of the environment from global actions affecting several fence fragments — for example, rain or wind;
- analyses the uniformity of the noise environment around the perimeter as a whole and in the comparison zones in particular — on this basis it suggests adjusting the sensitivity: reducing false alarms or raising the detection level;
- detects signs of deliberate jamming, of imitators planted in the communication line, and potential system defects.
The spatial-temporal comparison algorithm makes it possible to tell a person's impact on the fence from a wind gust or heavy hail: a person acts on the fence at a single point, while rain or hail acts on several sections at once.
Each sensor is configured individually:
- gain factor;
- lower working-frequency bound — from 1 to 100 Hz;
- upper working-frequency bound — from 100 to 400 Hz;
- spectral subtraction of the interference signal (switchable);
- 25/50/75 Hz notch filter;
- diagnostics of dangerous actions: opening the sensor, fence deformation (including cutting mesh), falling or a change of tilt angle;
- self-diagnostics of the sensor and of the sensing element.
The wide frequency range allows confident operation on different fence types even in a difficult interference environment.

Vibration sensors VD-3, VD-5, VD-5-K
The sensors are fastened directly to the fence and measure its vibration level — the energy applied to it. Local sensitivity allows choosing installation points flexibly — for example, at wickets or gates — and reduces the influence of vibrations of loosely fixed sections relative to the support posts.
The sensing element is a high-precision high-speed MEMS accelerometer with virtually no analogue path: the sensors can be installed close to sources of radio interference — radars, beacons, generators, transformers, high-voltage lines.
VD sensors are mounted on mesh and wire fences, fences of thin boards, pickets, thin metal (profiled sheet) or polycarbonate — the perimeter is protected both against climbing over and against destruction (cutting, bending back).
Recommended installation spacing:
- solid "profiled sheet" fencing — every 5–10 m;
- mesh fencing — on every section, roughly every 3 m;
- interconnected sections — every other one, roughly every 6 m;
- wooden and other non-solid fences — every 5 m;
- collapsible coping arms and deformable obstacles — every 5–10 m.
Installation comes down to connecting two twisted-pair cables and fastening the housing to the fence with the supplied plates. The mounting screws are under the sensor's cover — it cannot be removed without opening the housing, and an optical tamper with an active strobing reference-level source generates a notification of an opening attempt. The housing is potted with transparent silicone — protection against aggressive external environments.
The cable is not a sensing element, so the sensor can be placed anywhere on the fence and the cable routed in whatever way is convenient: inside the fence, in a tray, or fastened externally with cable ties.
Seismic sensors SD-3
SD-3 converts ground vibrations caused by an intruder's actions into an electrical signal by the piezoelectric effect. A special mechanical signal amplifier operating across the entire band of processed frequencies provides the highest sensitivity.
A 5 m installation spacing guarantees detection of an intruder in any weather and in any soil type — even with partial waterlogging.
The sensors can be placed:
- in front of or under the fence — recording the intruder's approach even before they touch the fence;
- inside the guarded perimeter — confirming the fact of penetration;
- anywhere detection of people or vehicles matters, regardless of physical barriers — including for forming a hidden security line.
Triboelectric sensors DD-1
DD-1 is an addressable preamplifier for the TD-1 triboelectric cable: it processes the signal from two inputs and passes it to the BOS-L linear unit. Up to 30 m of cable is connected to each input (per data sheet), so one unit covers up to 60 m of perimeter; the detection accuracy corresponds to the length of one arm — 30 m.
The TD-1 cable converts fence vibrations into an electrical signal by the triboelectric effect. This is the simplest and most affordable sensing element: installation means fastening with cable ties to the protected surface, and a damaged section can be restored without special tools.
Three application options:
- On mesh, wire, wooden, metal (profiled sheet) or polycarbonate fencing — protection against climbing over and destruction (cutting, bending back).
- On spiral razor-wire (AKL) screens, tin or polycarbonate coping arms — protection against climbing over with a ladder and guarding solid concrete and brick walls.
- In the ground — an anti-tunnel security line: the cable detects a person with a spade at 1–5 m (depending on the soil and settings), and excavation work with heavy machinery — up to 30 m. Suitable for guarding underground utilities.
Technical Specifications
Values are taken from the data sheets dated 24.07.2026.
Vibration sensors VD-5, VD-5-K
| Parameter | Value |
|---|---|
| Sensor type | MEMS accelerometer |
| Supply voltage range | 12–30 V |
| Power consumption | not more than 60 mW |
| High-pass filter cut-off (adjustable) | 4, 12, 25, 50 Hz |
| Low-pass filter cut-off (adjustable) | 50, 100, 200, 400 Hz |
| Band-pass filter: centre frequency / bandwidth | 25, 50, 100 Hz |
| Gain adjustment range (Ku) | 0–35 dB, step 5 dB |
| Sensitivity zone | not less than a standard fence section |
| Line output | RS-485 |
| Recommended cable | FTP 2×4×0.5 outdoor |
| Dimensions | not more than 120×60×35 mm |
| Mass | not more than 160 g |
| Operating temperature | −40…+50 °C |
Seismic sensor SD-3
| Parameter | Value |
|---|---|
| Sensor type | Piezoceramic |
| Supply voltage range | 12–30 V |
| Power consumption | not more than 60 mW |
| High-pass filter cut-off (adjustable) | 4, 12, 25, 50 Hz |
| Low-pass filter cut-off (adjustable) | 50, 100, 200, 400 Hz |
| Band-pass filter: centre frequency / bandwidth | 25, 50, 100 Hz |
| Gain adjustment range (Ku) | 10–45 dB, step 5 dB |
| Sensitivity zone (dry loam, vertical installation) | circle with a radius of 2.5 m |
| Line output | RS-485 |
| Recommended cable | FTP 2×4×0.5 outdoor |
| Dimensions | Ø 60; h = 48 mm |
| Mass (without cable) | not more than 225 g |
| Operating temperature | −40…+50 °C |
Triboelectric sensor DD-1
| Parameter | Value |
|---|---|
| Supply voltage range | 12–30 V |
| Power consumption | not more than 200 mW |
| Line output | RS-485 (line load 1/250) |
| Gain adjustment range (Ku) | 0–35 dB |
| Health monitoring | continuous, remote parameter control |
| Cable diameter through the cable entry | 5–8 mm |
| Reverse-polarity protection / housing tamper detection | yes |
| Operating temperature | −40…+50 °C |
Linear processing unit BOS-3-0 (BOS-L)
| Parameter | Value |
|---|---|
| Supply voltage range | 8–30 V |
| Power consumption (without connected equipment) | not more than 2 W |
| Maximum addressable sensors per line | 120 (RS-485) |
| Communication ports | 2× RS-485, Ethernet (LAN) |
| Mean time between failures | 60,000 h |
| Mass | not more than 0.20 kg |
| Operating temperature | −40…+50 °C |
Documentation
| Device | Passport (PS) |
|---|---|
| VD-5 | VD-5 PS |
| VD-5-K | VD-5-K PS |
| DD-1 | DD-1 PS |
| SD-3 | SD-3 PS |
| BOS-L | BOS-3-0 PS |